Squawk Box

September 2007 Issue

Leaks and Shorts

After sitting idle on a ramp for at least 10 months, the airplane underwent maintenance. A strong fuel odor was observed in the cabin; an exterior inspection failed to detect anomalies. The odor subsided. Once the engines were started and the fuel selector placed in crossfeed, the odor returned. After removing the floorboards, a heater duct running perpendicular to the crossfeed lines was observed to be in contact, causing corrosion. Pinhole leaks had developed in both lines, p/n 5300108-53 and -54.